NAC444.207. Isolation and flotation tanks.  


Latest version.
  •      1. The recirculation, filtration and disinfection systems of isolation and flotation tanks must complete no fewer than four turnover cycles between users of the tank.

         2. The maximum bathing load in a tank is one person.

         3. The solution in the tank must be disinfected by normal chlorination or bromination at 3.0 to 5.0 ppm.

         4. Notices must be posted in the vicinity of the tank in the manner and with the information required by NAC 444.530.

         5. The maximum temperature of the solution in the tank must not exceed 95°F (35°C).

         6. The tank must be designed or ventilated to prevent any hazardous concentration of fumes from toxic disinfectants under all circumstances of operation.

     (Added to NAC by Bd. of Health, eff. 11-1-88)