NAC445A.1846. Carson Region: V-Line Canal.  


Latest version.
  • The limits of this table apply to the body of water known as V-Line Canal from the Carson diversion dam to its division into the S and L Canals. V-Line Canal is located in Churchill County.

    STANDARDS OF WATER QUALITY

    V-Line Canal

    PARAMETER

    REQUIREMENTS

    TO MAINTAIN

    EXISTING HIGHER

    QUALITY

    WATER QUALITY

    STANDARDS FOR

    BENEFICIAL USES

    Beneficial Usea

    Livestock

    Irrigation

    Aquatic

    Contact

    Noncontact

    Municipal

    Industrial

    Wildlife

    Aesthetic

    Enhance

    Marsh

    Beneficial Uses

    X

    X

    X

    X

    X

    X

    X

    X

    Aquatic Life Species of Concern

    Temperature - °C

    DTb - °C

    S.V.

    ΔT

    ≤ 34

    ≤ 3

    *

    X

    pH - SU

    S.V.

    6.5 - 9.0

    X

    X

    *

    *

    X

    X

    *

    Dissolved Oxygen - mg/l

    S.V.

    ≥ 5.0

    X

    *

    X

    X

    X

    X

    Total Phosphorus

    (as P) - mg/l

    S.V.

    ≤ 0.33

    *

    *

    X

    X

    Total Ammonia

    (as N) - mg/l

    c

    *

    X

    Total Dissolved

    Solids - mg/l

    S.V.

    ≤ 500 or the 95th percentile (whichever is less).

    X

    X

    *

    E. coli - No./100 ml

    A.G.M.

    S.V.

    ≤ 126

    ≤ 576

    *

    X

    Fecal Coliform - No./100 ml

    S.V.

    ≤ 1,000

    X

    *

    X

    X

    X

    * = The most restrictive beneficial use.

    X = Beneficial use.

    a     Refer to NAC 445A.122 and 445A.1792 for beneficial use terminology.

    b     Maximum allowable increase in temperature above water temperature at the boundary of an approved mixing zone, but the increase must not cause a violation of the single value standard.

    c     The ambient water quality criteria for ammonia are specified in NAC 445A.118.

     (Added to NAC by Environmental Comm’n by R160-06, eff. 8-26-2008; A by R131-12, 12-20-2012)