Nevada Administrative Code (Last Updated: January 6, 2015) |
Chapter445A Water Controls |
UNDERGROUND INJECTION CONTROL |
Construction, Operation, Monitoring and Abandonment |
NAC445A.910. Factors for determining logging and testing requirements for Class II wells.
Latest version.
- To determine the logging and testing requirements for Class II wells, the Director will consider:
1. For surface casing intended to protect underground sources of drinking water in areas where the lithology has not been determined:
(a) Electric and caliper logs before casing is installed; and
(b) A cement bond, temperature or density log after the casing is set and cemented.
2. For intermediate and long strings of casing intended to facilitate injection:
(a) Electric, porosity and gamma ray logs before the casing is installed;
(b) Fracture finder logs; and
(c) A cement bond, temperature or density log after the casing is set and cemented.
(Added to NAC by Environmental Comm’n, eff. 10-21-87)—(Substituted in revision for NAC 445.42705)