NAC461A.180. Water connections.  


Latest version.
  •      1. Each mobile home stand must be provided with a water riser and a connection that is located and aligned to permit attachment in a workmanlike manner to a mobile home occupying the mobile home stand. The water riser must be located within 4 feet of the mobile home stand and the riser must be protected against damage above the ground.

         2. A water riser must have an inside diameter of at least three-fourths of an inch and must extend at least 4 inches above the ground. The outlet of a riser must be capped when a mobile home is not occupying the mobile home stand. Surface drainage must be diverted away from the location of the water riser.

         3. A water riser that serves a mobile home lot must be equipped with a shutoff valve.

         4. The manager shall take all necessary precautions to prevent the freezing of water supply lines, valves and risers, whether or not the mobile home stand is occupied. The manager shall protect the risers from the heaving and thawing of the ground if the mobile home park is in an area where periodic freezing is encountered. Where ground frosts occur, the shutoff valves must be protected.

         5. Inlets and outlets of fixtures with base attachments which may cause a cross-connection must be protected by a standard nonremovable device for the prevention of backflow or by a standard vacuum breaker that is installed at least 6 inches above the highest point of usage and is located on the discharge side of the last valve. Fixtures that are manufactured with integral vacuum breakers must be installed in accordance with the manufacturer’s instructions. Lawn hydrants must be protected by a standard, nonremovable device for the prevention of backflow.

     (Added to NAC by Mfd. Housing Div., eff. 6-29-84; A by R055-02, 7-18-2002)