NAC461A.250. Electric connections.  


Latest version.
  •      1. Each mobile home lot must have a connection to provide electricity for a mobile home which will occupy the lot. The connection must be located and arranged to permit attachment in a workmanlike manner to the mobile home.

         2. The equipment for providing electricity to a mobile home must be located not more than 20 feet away from the point where the feeder assembly is attached to the mobile home.

         3. The circuit conductors of the feeder must have adequate capacity for the loads to be supplied and must be capable of carrying a load of at least the same amperage as that of the electrical system of the mobile home being served.

     (Added to NAC by Mfd. Housing Div., eff. 6-29-84)