NAC512.164. Code of bell signals for hoisting.  


Latest version.
  •      1. At all mines where hoisting apparatus is used in the State of Nevada, the following code of bell signals must be adopted and used:

         (a) COMMAND SIGNALS

        

              Stop..........................................................................................................

                           1 Bell

              Lower Conveyance...................................................................................

                         2 Bells

              Raise Conveyance....................................................................................

                         3 Bells

              Hoist Persons............................................................................................

                      3-1 Bells

              Lower Persons..........................................................................................

                      3-2 Bells

              Hoist Slowly with Caution.......................................................................

                   3-3-1 Bells

              Lower Slowly with Caution.....................................................................

                   3-3-2 Bells

              Hoist Muck or Materials Only..................................................................

                   1-2-1 Bells

              Release Conveyance.................................................................................

                   2-1-2 Bells

              Repeat.......................................................................................................

                   2-2-2 Bells

        

    The conveyance must not be moved without a command signal. When persons are to be hoisted or lowered, they must enter the conveyance and close the door and then give the signal for the desired level, followed by “Hoist Persons” (3-1 Bells) or “Lower Persons” (3-2 Bells). Additional signals are:

         For blasting, 3-2-1 Bells, which the hoisting engineer shall acknowledge by raising and lowering the conveyance slightly.

         For an emergency, 9 Bells, followed by ringing the mine level signal for the level where the emergency exists.

         (b) MINE LEVEL SIGNALS

        

              Shaft Collar.....................................................................................................

              1-2 Bells

              First Level.......................................................................................................

              2-1 Bells

              Second Level...................................................................................................

              2-2 Bells

              Third Level......................................................................................................

              2-3 Bells

              Fourth Level....................................................................................................

              2-4 Bells

              Fifth Level.......................................................................................................

              2-5 Bells

              Sixth Level......................................................................................................

              4-1 Bells

              Seventh Level..................................................................................................

              4-2 Bells

              Eighth Level....................................................................................................

              4-3 Bells

              Ninth Level.....................................................................................................

              4-4 Bells

              Tenth Level.....................................................................................................

              4-5 Bells

        

         2. One copy of this code of bell signals must be posted on the gallows-frame, one before the engineer and one at each station. Other bell signals which are not in conflict with this code may be used for local conditions, but a table showing such other signals must be posted in connection with this code.

     [Inspector of Mines, Part 1 No. 19 subsecs. a-c, e & g, eff. 8-13-75]—(NAC A by Div. of Mine Inspection, 8-26-83)