Nevada Administrative Code (Last Updated: January 6, 2015) |
Chapter534A Geothermal Resources |
REGULATIONS OF COMMISSION ON MINERAL RESOURCES |
Abandonment and Plugging |
NAC534A.480. Abandonment of thermal gradient or observational well.
Latest version.
- For abandonment of a thermal gradient or an observational well, the following provisions apply:
1. If the well was drilled with air and no water was encountered, the hole must be backfilled with cuttings and a cement plug 50 feet long must be placed at the top of the well.
2. If the well was drilled with mud, the bore must be filled with mud, and a cement plug of 50 lineal feet must be placed at the top of the well.
3. The surface must be restored as near as practicable to its original condition.
(Added to NAC by Comm’n on Mineral Resources, eff. 11-12-85)